EFFECT OF CYCLONE INLET VELOCITY AND VORTEX FINDER HEIGHT ON COARSE WHEAT BRAN DUST SEPARATION

Document Type : Original Article

Author

Associate Prof. of Agric. Eng. Dep., Fac. of Agric., Suez Canal Univ., 41522 Ismailia, Egypt.

Abstract

Experimental study was performed for evaluating a vast number of equations derived from reviews to determine the performance of cyclone for overall collection efficiency, cut size diameter and pressure drop of cyclone. These equations were used based on the geometrical design of cyclones for operation at the ambient temperatures under different vortex finder heights (0.0, 0.05, 0.10, 0.15 and 0.20 m) and inlet velocities (9.3, 11.5, 18.5, 25.4 and 28.3 m/s). The cut size diameter of coarse wheat bran as inlet dust was estimated using direct empirical method and by Stock's number based on Euler's number. Both methods were also used to predict the overall collection efficiency. Experimental data were compared with the predictions of Lapple's theory and Iozia & Leith's logistic method. The results showed that only the pressures drop based on Cocker model in the range of 9.3 to 18.5 m/s inlet velocity proved accurate predictions. The operation at inlet velocity of 18.5 m/s was the best operational condition due to high collection efficiency of 96.4, 98.9, 98.5, 98.3 and 98.7%; and low pressure drop of 1173, 1324, 1249, 1137 and 1419 Pa at vortex finder height of 0.0, 0.05, 0.10, 0.15 and 0.20 m respectively, across the cyclone.

Keywords


Alexander, R. M. (1949): Fundamentals of cyclone design and operation. Proceedings of the Australian Institute of Minerals and Metals (New Series), 152/153, 202–228.
Azadi, M., Azadi, M. and Mohebbi, A. (2010): A CFD study of the effect of cyclone size on its performance parameters. Journal of Hazardous Materials, 182, 835–841.
Beeckmans, J. M. and kim, C. J. (1977): Analysis of the Efficiency of reverse flow cyclones, Can. J. Chem. Eng. 55, 640-643.
Blachman, M. W. and Lippmann, M. (1974): Performance characteristics of the multicyclone aerosol sampler, American Industrial Hygiene Association Journal, 35, 311–326.
Bose, P. K., Roy, K., Mukhopadhya, N. and Chakraborty, R. K. (2010): Improved theoretical modeling of a cyclone separator as a diesel soot particulate emission arrester, International Journal of Automotive Techno., Vol. 11, No. 1, pp. 1−10.
Bruce, R. M., Donald, F. Y. and Theodore, H. O. (2006): Fundamentals of Fluid Mechanics, John Wiley & Sons, Inc., 5th edition, ISBN 0-471- 7582-2.
Bryant, H. S., Silverman, R. W. and Zenz, F. A. (1983): How dust in gas affects cyclone pressure drop, Hydrocarbon Process, 62, 87–90.
Büttner, H. (1999): Dimensionless representation of particle separation characteristics of cyclones, J Aerosol Sci, 30, 1291–302.
Casal, J. and Martinez-Benet, J. M. (1983): A better way to calculate cyclone pressure drop, Chem. Eng., 90, 99–100.
Chan, W. H. (1984): Investigation of hydrodynamic behavior in cyclone separators, Ph.D. thesis, Laboratory for Power and Environmental Studies, State University, Buffalo (NY), U.S.A.
Chuah, T. G., Gimbun, J., Choong, Thomas S. Y. and Fakhru’l-Razi, A. (2003): Numerical Prediction of Cyclone Pressure Drop. Journal of Chemical Engineering and Environment, Vol. 2, No. 2, pp. 67-71.
Coker, A. K. (1993): Understand cyclone design, Chem. Eng. Progr. 28, 51–55.
Dewil, R., Baeyens, J. and Caerts, B. (2008): CFB cyclones at high temperature: Operational results and design assessment, Particuology, 6, 149–156.
Dirgo, J. (1988): Relationships between cyclone dimensions and performance, Ph.D. Thesis, Havarad University, USA.
Elsayed, K. and Lacor, C. (2013): The effect of cyclone vortex finder dimensions on the flow pattern and performance using LES. Computers & Fluids, Volume 71, 30 January 2013, Pages 224–239
Frank, M. W. (2003): Fluid Mechanics, McGraw-Hill, ISBN 0-07-283180-4.
Gil, A., Romeo, L. M. and Corte´s, C. (2001): Cold flow model of a PFBC cyclone, Powder Technology, 117, 207–220.
Hoekstra, A. J. (2000): Gas flow field and collection efficiency of cyclones, Ph.D. Thesis, Delft University of Technology, The Netherlands.
Hoffmann, A. C, Groot, M., Peng, W., Dries, H. W. A. and Kater J. (2001): Advantages and risks in increasing cyclone separator length, AIChE J., 47, 2452–60.
Hoffmann, A. C., De Jonge, R., Arends, H. and Hanrats, C. (1995): Evidence of the ''natural vortex length'' and its effect on the separation efficiency of gas cyclones, FiltrSeparat, 32, 799–804.
Iozia, D. L. and Leith, D. (1990): The logistic function and cyclone fractional efficiency, Aerosol Sci. Technol., 12, 598–606.
Ji, Z. L., Wu, X. L. and Shi, M. X. (1991): Experimental research on the natural turning length in the cyclone, Proceedings of Filtech Europa 91 Conference (Vol. 2, pp.583–589), Karlsruhe, Germany.
Jiao, J., Zheng, Y., Sun, G. and Wang, J. (2006): Study of the separation efficiency and the flow field of a dynamic cyclone, Sep. Purif. Technol., 49, 157–166.
Karagoz, I. and Kaya, F. (2007): CFD investigation of the flow and heat transfer characteristics in a tangential inlet cyclone, International Communications in Heat and Mass Transfer 34, 1119–1126.
Kuo, K. Y. and Tsai, C. J. (2001): On the theory of particle cutoff diameter and collection efficiency of cyclones, Aerosol and air Quality Research, (2001) Vol. 1, No. 1, pp. 47-56.
Lapple, C. E. (1950): Gravity and centrifugal separation, Industrial Hygiene Quarterly, 11, 40–47.
Lees, F. P. (2005): Loss Prevention in the Process Industries (Partially updated by S. Mannan), vols. 1–3, Elsevier/Butterworth-Heinemann, Oxford, UK.
Lim, K. S., Kim, H. S. and Lee, K. W. (2004): Comparative performances of conventional cyclones and a double cyclone with and without an electric field, Aerosol Science, 35, 103–116.
Moore, M. E. and McFarland, A. R. (1993): Performance modelling of single-inlet aerosol sampling cyclones, Environ. Sci. Technol., 27, 1842-1848.
Overcamp, T. J. and Scarlett, S. E. (1993): Effect of Reynolds number on the Stokes number of cyclones, Aerosol Sci. Technol., 19, 362– 370.
Pant, K., Crowe, C. T. and Irving, P. (2002): On the design of miniature cyclones for the collection of bioaerosols, Powder Technology, 125, 260– 265.
Qian, F., Zhang, J. and Zhang, M. (2006): Effects of the prolonged vertical tube on the separation performance of a cyclone, J. Hazard. Mater, 136, 822–829.
Ramachandran, G., Leith, D., Dirgo, J. and Feldman, H. (1991): Cyclone optimization based on a new empirical model for pressure drop, Aerosol Science and Technology, 15, 135–148.
Safikhani, H., Akhavan-Behabadi, M., Shams, M. and Rahimyan, M. H. (2010): Numerical simulation of flow field in three types of standard cyclone separators, Advanced Powder Technol., 21, 435–442.
Saltzman, B. E. and Hochstrasser, J. M. (1983): Design and performance of miniature cyclones for respirable aerosol sampling, Environ. Sci. Techno., 17, 418-424.
Shepherd, C. B. and Lapple, C. E. (1939): Air Pollution Control: A Design Approach, In Cyclones" 2nd Edition, C. David Cooper, and F. C. Alley, pp 127-139, Illinois: Woveland Press Inc.
Stairmand, C. J. (1951): The design and performance of cyclones, Transactions of the Institution of Chemical Engineering 29, 357–383.
Svarovsky, L. (1981): Solid-gas separation. Handbook of Powder Technology, vol. 3, Chap. 1–3, Elsevier Scientific Publishing Company.
Svarovsky, L. (1986): Solid–gas separation, In D. Geldart (Ed.), Gas fluidization technology, New York, John Wiley and Sons Ltd (Chapter 8):
Swamee, P. K., Aggarwal, N. and Bhobhiya, K. (2009): Optimum design of the cyclone separator, American Institute of Chemical Engineers (A.I.Ch.E.) 55, 2279–2283.
Wang, L. (2004): Theoretical Study of Cyclone Design, Ph.D. Thesis, Texas A&M University, College Station, USA.
Yalcin, T., Kaukolin, E. and Byers, A. (2003): Axial inlet cyclone for mineral processing applications, Minerals Engineering, 161375–1381.
Zhu, Y. and Lee K. W. (1999): Experimental study on small cyclones operating at high-flow rates, J. Aerosol Sci., 30, 1303–1315.