SIMULATION MODEL OF ENERGY BALANCE FOR POULTRY HOUSES

Document Type : Original Article

Authors

1 Graduate Student of Agric. Eng. Dep., Fac. of Agric., Benha Univ., Egypt.

2 Fac. of Agric., Benha Univ., Egypt.

Abstract

The main aim of this research was to develop a simulation model of energy balance of the poultry house to predict the energy gain or loss of poultry houses that made of different materials in order to save energy and reduce costs. This could be achieved through studying the external loads are transmission, fenestration, perimeter, ventilation and infiltration at different poultry houses. The results showed that the energy requirement for heating poultry house decreases with increasing chicken age (40 days). The energy requirement for heating was decreased from 3716.75 to 247.65, 2731.31 to 10.79, 2417.98 to 66.14 and 2418.06 to 66.18 Kwh for first, second, third and fourth houses, respectively, when the chicken age increased from 1 to 40 days in Faiyum city. The energy requirement for heating was decreased from 6602.23 to 701.29, 5030.31 to 364.65, 4534.72 to 255.98 and 4534.86 to 255.99 Kwh for first, second, third and fourth houses, respectively, when the chicken age increased from 1 to 40 days in Benha city. The energy requirement for ventilation was increased from 1517.24 to 4083.08, 1325.53 to 3326.87, 1262.20 to 3084.95 and 1262.21 to 3085.00 Kwh for first, second, third and fourth houses, respectively, when the chicken age increased from 1 to 40 days in Faiyum city. The energy requirement for ventilation was increased from 2373.09 to 6793.56, 1991.44 to 5477.08, 1867.80 to 5060.30 and 1867.81 to 5060.41 Kwh in Benha city, when the chicken age increased from 1 to 40 days. The model results were in a reasonable agreement with the experimental ones.

Keywords


Alam, M. S., M. R. Alam and K. K. Islam (2005). Energy flow in agriculture: Bangladesh. Am. J. Environ. Sci., 3: 213 - 220.
Arora, C. P. (2006). Refrigeration and air conditioning. Second edition. McGraw-Hill. New Delhi.
ASAE (2003). Design of ventilation systems for Poultry and Livestock Shelters. ASAE, St Joseph, Michigan, pp: 634 - 652. Retrieved from: http://edis.ifas.ufl.edu.
ASHRAE (2001). Handbook heating, ventilating, and air-conditioning application Atlanta, GA: American Society of Heating, Refrigerating and Air-conditioning Engineers, Inc: 90.1.
ASHRAE (2003). Handbook Heating, Ventilating, and Air-Conditioning system and equipement. Atlanta, GA: The American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc: 12.14.
ASHRAE (2009). Handbook heating, ventilating, and air-conditioning application Atlanta, GA: American Society of Heating, Refrigerating and Air-conditioning Engineers, Inc: 4.2.
ASHRAE (2013). Handbook heating, ventilating, and air-conditioning application Atlanta, GA: American Society of Heating, Refrigerating and Air-conditioning Engineers, Inc: 34.15.
Eekeren, N. V., A. Maas, H. W. Saatkamp, and M.Verschuur, (2006). Small-scale chicken production. Fourth edition, Agromisa Foundation and CTA, Wageningen.
Hamrita, T.K. and B. Mitchell (1999). Poultry environment and production control and optimization. A summary of where we are and where we want to go. Trans. ASAE, 42: 479 - 483.
Holman, J. P. (1997). Heat Transfer, 8th edition. McGraw-Hill. 696 pp.
Ibrahim, A., A. A. El-Sebaii, M. R. Ramadan and S. M. El-Broullesy (2011). Estimation of Solar Irradiance on Inclined Surfaces Facing South in Tanta, Egypt.  IJRER, 18-25
Jekayinfa, S. O. (2007). Energetic Analysis of Poultry Processing Operations. Leonardo Journal of Sciences, 10: 77 – 92.
Mutai, E. B. K., P. O. Otieno, A. N. Gitau, D. O. Mbuge and D. A. Mutuli (2011). Simulation of the Microclimate in Poultry Structures in Kenya. Journal of Applied Sciences Research, Engineering and Technology, 3 (7): 579 – 588.
Osorio, J. A. O., I. D. F. Tinȏco, K. S. O. Rocha, M. A. Martins and M. O. De Paula (2011). Modeling and experimental validation to estimate the energy balance for a poultry house with misting cooling. Dyna., 78(170): 167-174.
Schauberger, G., M. Piringer and E. Petz (2000). Steady state balance model to calculate the indoor climate of livestock buildings demonstrated for finishing pigs. Int. J. Biometeorol., 43(17): 154-162.