In hot and humid regions such as around the Equator, coastal areas and Mediterranean basin, crop growth in greenhouses during hot and humid summer is almost impossible because of the excess temperatures accumulated inside causing plant stress and welt. The aim of this experimental work was to investigate the effects of a developed evaporative cooling system on the greenhouse macroclimate and productivity of tomato crop. Two similar gable-even-span greenhouses were utilized at EL-Sabahia Horticultural Research Station, Alexandria (as a Costal region), to produce tomato crop during the summer seasons of 2014 and 2015. Each greenhouse was equipped with a complete evaporative cooling system. One of them was modified (MECS) by obstruct the humid ambient air by a granule silica gel sieve. Whereas it absorbs the excess moisture of ambient air prior to passing through the cooling pads. The other one used the traditional fan-pad evaporative cooling system, (FPECS). The obtained results illustrated that, the averages air temperature after leaving the cooling pad, greenhouse air temperatures, relative humidity, efficiency and vapor pressure deficit were (21.6 - 28.2 oC), (29.2-33.4 oC), (65.2-71.4%), (89.2-62.1%) and (1.39-1.50 kPa) for MECS and FPECS greenhouses, respectively. The maximum greenhouse temperature decreased below the outside temperature by 2.9 oC for MECS while, it increased by 1.6 oC over it for FPECS. The percentages increase in early yield, number of fruit per plant, fruit weight, total yield per plant and total yield per feddan were 14.07, 9.43, 8.00, 18.15 and 18.13%, respectively for MECS greenhouse over FPECS greenhouse in 2014 season, while they were 12.41, 12.98, 7.90, 22.06 and 21.97%, respectively in 2015 season.

Keywords

Main Subjects


Abd El-Mageed, A.H.A. and N. Gruda (2009). Performance of different tomato genotypes in the arid tropics of Sudan during the summer season. II. Generative Development. Journal of Agriculture and Rural Development in the Tropics and Subtropics. 110(2): 147–154.
Abdellatif, S.M., M.M.M. Ibrahim and M.M.H. El-Lithy (2010). A comparative study on two different evaporative cooling systems for producing cucumber crop under hot-humid summer conditions. J. Soil Sci. and Agric. Eng., Mansoura Univ., 1 (10):1015-1036.
Adams, S.R., K.E. Cockshull and C.R.J. Cave (2002). Effect of temperature on the growth and development of tomato fruits. Annals Bot. 88, 869-877.
Adil, A.H.; N. Gruda, and B. Geyer (2004). Effects of temperature and grafting on the growth and development of tomato plants under controlled conditions. Rural poverty reduction through research for development and transformation, berlin, October 5-7, 2004.
Afonsoa, M.R.A. and V. Jr. B. Silveira (2005). Characterization of equilibrium conditions of adsorbed silica–gel/water bed. according to Dubinin–Astakhov and Freundlich. Engenharia Térmica (Thermal Engineering), 4(1): 3-7.
Argus, (2009). Understanding and Using VPD. Argus Control System LTD www.agruscontrols.com, Canada V4B 3Y9.
ASHRAE, (2010). Psychrometrics, American Society for Heating, Refrigeration, and Air Conditioning Engineers Fundamentals. SI Ed. Atlanta, USA. Ch 6: 6.1-6.17,
Autogrow, (2012). Vapour Pressure Deficit Calculator in Excel Spreadsheet, Autogrow System Ltd. (www.autogrow.com)
Bhatia, A. B.E. (2012). Principles of Evaporative Cooling System. PDHonline Course M231 (4 PDH). pp. 56. www.PDHonline.org
Bora, A., P. Saini, R. Bora, S. R. Purohit, A. Bora and S. K. Tripathy (2017). Desiccant evaporative cooling system. Intern. J. of Sci. Develop. and Res., (IJSDR), April 2017, 2 (4): 232-335.
Bourouni, K. (2008). Greenhouses Cooling: intelligent technologies using direct contact heat exchangers and challenges of desiccants. Atelier Mediterraneen sur les Nouvelles Technologies de Recyclage des Eaux Non Conventionnelles dans les cultures protégées 28 Avril – 1er Mai 2008.
Davies, P.A. (2005). A solar cooling system for greenhouse food production in hot climates. Solar Energy, 79 : 661-668.
El-Bakhashwan, M.K., G.D.M. Youssef, Salwa S. Hanna and Sh.M. Abdel-Ghafar (2013). Solar energy utilization for regeneration of moist silica gel. Egyptian J. of Agric. Res. 3rd International Conference for Agricultural and Bio-Engineering. (Engineering Application for Sustainable Agricultural Development) – 24 Nov. 2013. 91 (2 B) 647 – 671.
Evaptainers, (2014). The Science of Evaporative Cooling. http://www.Evaptainers .com /updates/2014/8/6/the-sciance-of-evaporative-cooling, August 7, 2014.
Farmahini, F. M.; S. Delfani and J. Esmaeelian (2012). Exergy analysis of evaporative cooling to select the optimum system in diverse climates. Energy, 40: 250–257
Franco, A., D.L. Valera, and A. Peña (2014). Energy efficiency in greenhouse evaporative cooling techniques: Cooling boxes versus cellulose pads. Energies, 2014, 7: 1427-1447.
Garzoli, K.V. (1989). Cooling of greenhouses in tropical and sub-tropical climates. Acta Horticult. 257: 93–100.
Ho, L.C. (1996). The mechanism of assimilate partitioning and carbohydrate compartmentalization in fruit in relation to the quality and yield of tomato. J. Exp. Bot. 47: 1239-1243.
Hurd, R.G. and C.J. Graves (1985). Some effects of air and root temperatures on the yield and quality of glasshouse tomatoes. Journal of Horticultural Science 60: 359-371.
Islam, M.T. (2011). Effect of temperature on photosynthesis, yield attributes and yield of tomato genotypes. Int. J. Expt. Agric. 2(1):8-11, (January 2011)
Jamaludin, Diyana; D. Ahmad; R. Kamaruddin; and H.Z.E. Jaafar (2014). Microclimate inside a tropical greenhouse equipped with evaporative cooling pads.  Pertanika J. Sci. & Technol., 22 (1): 255 - 271 (2014).
Jones, Jr. B. (2007). Tomato Plant Culture: In the Field, Greenhouse, and Home Garden, 2nd Boca Raton, FL: CRC Press. Taylor & Francis Group, LLC.
Joudi, Kh.A. and M.M. Hasan (2013). Cooling and heating a greenhouse in Baghdad by a solar assisted desiccant system. J. Eng., 933, 8 (19) 933-951.
Kalloo, D. (1985). Tomato. Allied Publishers Private Ltd. 13/14 Asaf Ali Road, New Delhi-110002. p 172-202.
Katsoulas, N.; D. Savas; I. Tsirogiannis; O. Merkouris; and C. Kittas (2009). Response of an eggplant crop grown under Mediterranean summer conditions to greenhouse fog cooling. Sci. Hortic., 123: 90–98.
Kittas, C.; T. Bartzanas and A. Jaffrin (2003). Temperature gradient in a partially shaded large greenhouse equipped with evaporative cooling pads. Biosystems Engineering, 85(1):87-94.
López, A.; D. L. Valera; F. D. Molina-Aiz; and A. Peña (2012). Sonic anemometry to evaluate airflow characteristics and temperature distribution in empty Mediterranean greenhouses equipped with pad–fan and fog systems. Biosyst., Eng. 113: 334–350.
Lychnos, G. (2010). Feasibility of a solar-powered liquid desiccant cooling system for greenhouses. Ph.D. Thesis, AstonUniversity.
Lychnos, G. and P. A. Davies (2008). A solar powered liquid-desiccant cooling system for greenhouses. ActaHortic., 2008.797.11:  International Workshop on Greenhouse Environmental Control and Crop Production in Semi-Arid Regions.
Mishra, G. K., L. Yadav and M. Kumar (2016). A Review of desiccant based cooling systems using silica gel. Imperial J. of Interdisciplinary Res. (IJIR), 2 (12): 1224-1232.
Mehmet, A.D. and H.S. Hasan (2015). Performance analysis of a greenhouse fan-pad cooling system: gradients of horizontal temperature and relative humidity. Journal of Agricultural Sciences. 21: 132-143
Mohammad, A.T., S.B. Mat, M.Y. Sulaiman, K. Sopian, and A.A. Al-Abidi (2013). Historical review of liquid desiccant evaporation cooling technology. Energy and Buildings, 67: December 2013: 22–33.
Montero, J.I. (2006). Evaporative cooling in greenhouses: Effect on microclimate, water use efficiency, and plant response. ActaHortic. 719: 373–384.
Montero, J.I., and I. Segal (1993). Evaporative cooling of greenhouses by fogging combined with natural ventilation and shading. Proc. of the Intern. Workshop on Cooling Systems for Greenhouses. Agritech, May 2-6.
Nguyen, T. N., L. H. Tang, Y. K. Peng, J. Y. Ni, and Y. N. Chang (2015). Effects of Composite Inorganic, Organic Fertilizer and Foliar Spray of Multi-nutrients on Growth, Yield and Quality of Cherry Tomato. J. Agr. Sci. Tech., 17: 1781-1788.
Pressman, E., M.M. Peet and D.M. Pharr (2002). The effect of heat stress on tomato pollen characteristics is associated with changes in carbohydrate concentration in the developing anthers. Annals of Botany. 90: 631-636.
Rafique, M.M., Sh. Rehman, A. Lashin and N. Al-Arifi (2016). Analysis of a solar cooling system for climatic conditions of five different cities of Saudi Arabia. Energies, 2016, pp, 13.
Saeed, A., Kh. H., A. A. Khan and S. Iqbal (2007). Heat tolerance studies in tomato (Lycopersicon esculentum Mill.). Int. J. Agri. Biol., 9 (4): 649–652.
Sato, S., M.M. Peet and J.F. Thomas (2000). Physiological factors limit fruit set of tomato (Lycopersicon esculentum Mill.) under chronic, mild heat stress. Plant Cell Environ 23:719-726.
Sethi, V.P. and S.K. Sharma (2007). Survey of cooling technologies for worldwide agricultural greenhouse applications. Solar Energy. 81: 1447–1459.
Shamshiri, R., and W.I. Wan Ismail. (2014). Data acquisition for monitoring vapor pressure deficit in a tropical lowland shelter house. Plant Prod. Res. J. Appl. Sci., Engin. and Techn., 7(20): 111-122.
Shamshiri, R., C.M. Hasfalina, A.J. Zakaria, P.Van. Beveren, D.B. Ahmad, W.I.W. Ismail (2016). Membership function model for defining optimality of vapor pressure deficit in closed-field cultivation of tomato. Acta Hort. (ISHS) 63: 1-7.
Singh, R.P., P.V. Vara Prasad, K. Sunita, S.N. Giri and K.R. Reddy (2007). Influence of high temperature and breeding for heat tolerance in cotton. Adv. Agron., 93: 313–85
Tahat, M. A. (2001). Heat–pump/energy-store using silica gel and water as working pair. Applied Energy, 69: 19-27.
Vollenweider, P. and M.S. Gunthardt-Goerg (2005). Diagnosis of abiotic and biotic stress factors using the visible symptoms in foliage. Environ. Pollut. 137:455-465.
Vox, G.M. Teitel, A. Pardossi, A. Minuto, F. Tinivella and E. Schettini (2010). Sustainable Greenhouse Systems. 2010. Nova Science Publishers, Inc., 79 pp.
Wikipedia, (2013). The free encyclopedia. http://en.wikipedia.org /wiki/Silica_gel.
Youssef, G.D.M. (2007). A thermal storage system for greenhouse energy conservation. Ph.D. Thesis, Fac. of Agric., AlexandriaUniv.
Youssef, G.D.M. and Yakout, T.R. (2015). Effect of externally mounted shading screen on microclimatic conditions of greenhouse cantaloupe crop equipped with evaporative cooling system. J. Soil Sci. and Agric. Eng., Mansoura Univ., 6 (5): 667-685., 2015.
Youssef, G.D.M., T. R. Yakout, and Doaa, M. Mostafa (2015). Improving performance of the evaporative cooling system inside the greenhouses and its effect on tomato productivity. Alex. Sci. Exch. J. 36(1):80-94.