APPLYING DIRECT EVAPORATIVE COOLING SYSTEM FOR CONTROLLING ENVIRONMENTAL CONDITIONS IN RABBIT HOUSES

Document Type : Original Article

Author

Lecturer of Agric. Eng., Fac. of Agric., Zagazig Univ., Egypt.

Abstract

Heat stress is a major problem that faces rabbit’s breeders. This problem adversely affects rabbit's growth and reduces the resistance to diseases. The present research was carried out to apply and evaluate the performance of a direct evaporative pad cooling system in rabbit houses to control environmental conditions. The direct evaporative pad cooling system performance was studied as a function of change in pad thickness (10 and 15 cm), water flow rate (3, 5 and 7 L/min.m2) and rabbit stocking density with an approximate average (0.5 and 1.0 rabbit/m2). Performance evaluation of the evaporative pad cooling system was carried out in terms of temperature reduction, cooling efficiency, temperature-humidity index, daily body weight gain and mortality ratio. The experimental results clarified that values of temperature reduction (7.3 and 6.8 oC), cooling efficiency (94.92 and 90.91 %), temperature-humidity index (26.30 and 27.40 oC), daily body weight gain (38.80 and 38 g/rabbit/day) and mortality ratio (0.2 and 0.4 %) are in the optimal limits under conditions of 15 cm pad thickness and 5 L/min.m2 water flow rate for rabbit stocking densities of 0.5 and 1.0 rabbit/m2, respectively.

Main Subjects


Abdel-Samee, A.M. (1997). Response of New Zealand white rabbits to thermal stress and its amelioration during winter and summer of North Sinai, Egypt. Journal of Arid Environments 36: 333–342.
Dağtekin M., C. Karaca and Y. Yıldız (2009). Long Axis Heat Distribution in a Tunnel-Ventilated Broiler House Equipped With an Evaporative Pad Cooling System. Anim. Prod. Sci., 49: 1125-1131.
Dağtekin, M., C. Karaca and Y. Yıldız (2006). Performance Characteristics of a Pad Evaporative Cooling System in a Broiler House in a Mediterranean Climate. Biosyst. Eng., 103: 100-104.
Dağtekin, M., C. Karaca, Y. Yildiz, A. Basçetinçelik and Ö. Paydak (2011). The effects of air velocity on the performance of pad evaporative cooling systems. African Journal of Agricultural Research 6 (7): 1813-1822.
Darwesh, M. R. (2015). Effect of evaporative cooling system on microclimatic circumstances of commercial closed laying-hens house under delta-zone climatic conditions. Misr J. Agric. Eng., 32 (2): 885 – 908.
Darwesh, M., S. Abouzaher, T. Fouda and M. Helmy (2007). Effect of using pad manufactured from agricultural residues on the performance of evaporative cooling system. Misr J. Agric. Eng., 24(4): 1023- 1043.
Franco, A., D.L.Valera,  A. Madue˜no and A. Pe˜na (2010). Influence of water and air flow on the performance of cellulose evaporative cooling pads used in Mediterranean greenhouses. Trans. ASABE 53 (2): 565–576.
Gunhan, T., V. Demir and A.K. Yagcioglu (2007). Evaluation of the Suitability of Some Local Materials as Cooling Pads.Biosys. Eng., 96: 369-377.
Ibrahim, M. H., E. A. Abdel Ghaffar, M. F. Hassan and A. M. Bayomy (2011). Improve the productivity of broilers using an evaporative cooling system. Misr J. Agric. Eng., 28(4): 1094 – 1118.
Karaca, C., Y. Yıldız, M. Dağtekin and Z. Gümüş (2016). Effect of water flow rate on cooling effectiveness and air temperature change in evaporative cooling pad systems. Environmental Engineering and Management Journal15 (4): 827-833.
Khobragade, N. N. and S. C. Kongre (2016). Experimental performance of different evaporative cooling pad material of direct evaporative cooler in hot and dry region. International Journal of Innovative Technology and Research (IJITR) 4 (3): 2920 – 2923.
Koca, R. W., W. C. Hughes and L. L. Christianson (1991). Evaporative cooling pads: Test procedure and evaluation. Applied Engineering in Agriculture 7 (4): 485-490.
Liao, C. M. and K. H. Chiu (2002). Wind Tunnel Modeling the System Performance of Alternative Evaporative Cooling Pads in Taiwan Region. Building Environment 37: 177-187.
LPHSI (1990). Livestock and Poultry Heat Stress Indices. Agricultural Engineering Guide. Clemson University, Clemson SC., 29634, USA.
Marai, I. F. M., M. S. Ayyat and U. M. Abd El-Monem (2001). Growth performance and reproductive traits at first parity of New Zealand White female rabbits as affected by heat stress and its alleviation under Egyptian conditions. Tropical Animal Health and Production 33: 1-12.
Marai, I. F. M., A. A. M. Habeeb and A.E. Gad (2002). Rabbits’ productive, reproductive and physiological performance traits as affected by heat stress: a review. Livestock Science 78 (2): 71–90.
Mashaly, M. M., G. L. Hendricks, M. A. Kalama, A. E. Gehad, A. O. Abbas and P. H. Patterson (2004). Effect of heat stress on production parameters and immune responses of commercial laying hens. Poultry Science 83: 889-94.
Petek, M., S. Dikmen and M. M. Oğan (2012). Performance analysis of a two stage pad cooling system in broiler houses. Turk. J. Vet. Anim. Sci. 36(1): 21-26.
Porumb, B., P. Ungureşan, L. F. Tutunaru, A. Şerban and M. Bălan (2016). A review of indirect evaporative cooling technology. Energy Procedia 85: 461 – 471.
Willmer P., G. Stone and J. Johnston (2000). Environmental physiology of animals. 1st ed. Blackwell Scientific Publications, Oxford. 672 pp.
Yıldız, Y., C. Karaca, M. Dağtekin (2010). Environmental control in livestock shelters: Ventilation, heating, cooling and illumination (in Turkish) Hasad Yayıncılık Ltd. Şti., P.K. 35, Ümraniye-3470-İstanbul.