MAXIMIZE THE UTILIZATION OF TRADITIONAL COOLING UNITS FOR BROILER HOUSES

Document Type : Original Article

Authors

Lecturers of Agric. Eng., Fac. of Agric. Eng., Al-Azhar Univ., Assiut, Egypt.

Abstract

This research was conducted in a poultry farm within the poultry fattening project in Sohag Governorate, Egypt. Latitude 26.556 and longitude 31.655, village of Al-Ahawi. This research aims to maximize the utilization of the current cooling system for the broiler poultry houses. The experiment was conducted in station No. 2 using 6 houses at a poultry age 35 days on 3 July 2018 where the mean ambient temperature was 30.5 oC and the mean relative humidity was 47.4 %. The operating time of the cooling units under test was 8 hours, from 9:00 am to 5:00 pm. It should be noted that before 9:00 am all the houses were cool under the operating conditions of house4. The data showed that highest temperature increase was achieved at operating house 3 conditions (The cooling units are operated with nozzles arrangement (3) and air speed 2.5 m/s) with a value range of 19.3 : 26.3 oC (Avg. = 24.7 oC) while the relative humidity ranged from 64.1 to 69.3 % (Avg. = 65.7 %). It is not recommended that the fans run at operating points 3 (Air speed 2.5 m/s) under the same experimental conditions. It is recommended that reduce the number of nozzles inside cooling units from 12 to 8 or 10 nozzles leading to decrease relative humidity under the same experimental conditions. To reduce evaporation rate and rationalization of water consumption by 22 l/hr, cooling units are used under operating conditions of houses 5 or 6 compared to house 4. Operating conditions for houses number 5 and 6 give total energy and cooling efficiency near normal operating conditions (house 4). But rationalization of water is a major reason to urge on change normal operating of the traditional cooling system and move forward to replace those traditional systems with the latest systems.

Keywords

Main Subjects


Ashrae. (1983). Evaporative Air-cooling Equipment. Chapter 4. Equipment Handbook. American Society of Heating, Refrigeration and Air-Conditioning Engineers. Atlanta, Georgia, USA.
Cobb, (2012). Broiler management guide. s.l.:s.n.
Heidarinejad G., M. Bozorgmehr, S. Delfani, and J. Esmaeelian. (2009). Experimental investigation of two-stage indirect/direct evaporative cooling system in various climatic conditions, Building and Environment. 44: 2073–2079.
Johann P. T. (2015). Design and performance evaluation of a HYDROSOL space heating and cooling system. Thesis presented in partial fulfilment of the requirements for the degree of Master of Engineering (Mechatronic) in the Faculty of Engineering at Stellenbosch University. Stellenbosch University https://scholar.sun.ac.za.
John P., (2006). Benefits of Upgrading from Two-Inch to Six-Inch vaporative Cooling Pads on Broiler Farms. Agricultural & Natural Resource Engineering Applications. Department of Agricultural and Biological Engineering. ANREA – 061.
Lemouari M., M. Boumaza, and A. Kaabi. (2009). Experimental analysis of heat and mass transfer phenomena in a direct contact evaporative cooling tower. Energy Conversion and Management. 50(6):1610-1617.
Ralebhat Rahul, Kothmire Pramod and Sardeshpande Vishal (2016). Low cost cooling system for poultry shed. International Engineering Research Journal (IERJ) Special Issue., 1271-1275, June 2016, ISSN 2395-1621, www.ierjournal.org.