MANUFACTURE AND PERFORMANCE EVALUATION OF A HORIZONTAL SINGLE-PASS ANIMAL FEED PELLETS COOLER

Document Type : Original Article

Authors

1 Prof. and Head of Ag. Eng. Dept., Fac. of Ag., Zagazig Univ., Egypt.

2 Lecturer of Ag. Eng., Ag. Eng. Dept., Fac. of Ag., Zagazig Univ., Egypt.

Abstract

The present research was carried out to manufacture and evaluate the performance of a horizontal single-pass animal feed pellets cooler to improve product quality. The cooler performance was studied as a function of change in pellets feed rate, conveyor chain speed and airflow rate. Performance evaluation of the horizontal cooler was carried out in terms of final pellets moisture content, cooling efficiency, pellets durability, energy requirements and cooling cost.
The experimental results revealed that final pellets moisture content, cooling efficiency, pellets durability, energy requirements and cooling cost are in the optimum region under the following conditions:
-          Pellets feed rate of 2.2 Mg/h,
-          Conveyor chain speed of 2 cm/s,
-          Airflow rate of 12 m3/s.

AACC. (2000). Approved Methods of AACC, 10th Ed., American Association of Cereal Chemists, St. Paul, MN.
Andersson, D. and D. Johansson (2008). Mathematical model for countercurrent feed pellet cooler. M. Sc. Thesis. Chalmers of University Technology.  Göteborg, Sweden.
Brooker, D.B., F.W. Bakker-Arkema, and C. W. Hall. (1992). Drying and Storage of Grains and Oilseeds. Van Nostrand Reinhold. New York, NY.
Harper, Allen. (1998). The importance of pellet quality in hog feeding. Livestock Update.
                Available at: http://www.ext.vt.edu/news/periodicals/livestock/aps-98_09/aps-969.html.
Heldman, D.R. and D.B. Lund. (2007). Handbook of Food Engineering. Second Edition. CRC Press. Boca Raton, FL.
Kaddour, O. and S.  Alavi (2010). Manufacture and evaluation of a single-pass rotary cooler for aquatic feed pellets. Journal of Food Process Engineering 33: 585–605.
Maier, D.E. (1988). The counterflow cooling of feed pellets. M.S. Thesis. MichiganStateUniversity. East Lansing, MI.
Steven L. F. (2008). Optimal sizing of a counterflow cooler for feed pellets. M.S. Thesis. Oklahoma State Univ. Stillwater, Oklahoma.